Sensing range 80 ... 2000 mm LED green solid: Power-on flashing: program function object detected LED yellow solid: switching state switch output flashing: program function LED red normal operation: "fault" program function: no object detected Electrical specifications Synchronization bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms Synchronization frequency Common mode operation ≤ 30 Hz Input type 1 program input, operating range 1: -UB ... +1 V, operating range 2: +4 V ... +UB input impedance: > 4.7 kΩ; program pulse: ≥ 1 s Output Output Switch point A1: 220 mm Switch point A2: 2100 mm output function: Window mode output behavior: NO contact |
|
Compliance with standards and directives Standard conformity Standards EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Approvals and certificates |
Adjustment range 120 ... 2000 mm
Dead band 0 ... 80 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 180 kHz
Response delay approx. 150 ms
Indicators/operating means
Operating voltage UB 10 ... 30 V DC , ripple 10 %SS
No-load supply current I0 ≤ 50 mA
Input/Output
Multiplex operation ≤ 30 Hz / n , n = number of sensors , n ≤ 5
Input
Output type 1 switch output PNP , Normally open/closed , programmable
Rated operating current Ie 200 mA , short-circuit/overload protected
Voltage drop Ud ≤ 2.5 V
Repeat accuracy ≤ 0.5 % of switching point
Switching frequency f ≤ 3.3 Hz
Range hysteresis H 1 % of the set operating distance
Temperature influence < 2 % of far switch point
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP65
Material
Housing nickel plated brass; plastic components: PBT
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 140 g
Factory settings
EAC conformity TR CU 020/2011
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V