Ürünler

PEPPERL+FUCHS RLK28-8-H-2000-IR-Z.31.116 CİSİMDEN YANSIMALI FOTOELEKTRİK SENSÖR

Technical Data

General specifications
Detection range 20 ... 2000 mm
Black/White difference (6 %/90 %) < 40 %
Diameter of the light spot approx. 70 mm at a distance of 2000 mm
Angle of divergence transmitter 2°
receiver 2°
Ambient light limit 50000 Lux
Functional safety related parameters
MTTFd 620 a
Mission Time (T
M) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green
Function indicator 2 LEDs yellow
ON: object inside the scanning range
OFF: object outside the scanning range
Control elements Sensing range adjuster , Light-on/dark-on changeover switch
Electrical specifications
Operating voltage UB 12 ... 240 V AC/DC
Power consumption P
0 3.5 VA
Output
Switching type light/dark on, switchable (selectable, light/dark switching is only
activated if the receiver has 'dark on' selected.)
Signal output Relay, 1 alternator
one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), pro
grammable
adjustment interval 0.1 ... 10 s
Ambient conditions
Ambient temperature -40 ... 60 °C (-40 ... 140 °F)
Storage temperature -40 ... 75 °C (-40 ... 167 °F)
Mechanical specifications
Degree of protection IP67
Connection terminal compartment with 8 spring-loaded terminals for wire
cross section 0.5 ... 1.5 mm
2, insulation stripping 7.5 ... 8.5 mm,
M16 x 1.5 cable gland
Material
Housing Plastic ABS
Optical face Plastic pane
Mass 112 g
Compliance with standards and directi
ves
Directive conformity
Low Voltage Directive 2006/95/EC EN 60947-5-2:2007+A1:2012
EMC Directive 2004/108/EC EN 60947-5-2:2007+A1:2012
Standard conformity
Product standard EN 60947-5-2:2007+A1:2012
IEC 60947-5-2:2007 + A1:2012
Standards UL 60947-5-2: 2014
EN 62471:2008
Approvals and certificates
EAC conformity TR CU 020/2011
TR CU 004/2011
Protection class II, rated voltage
250 V AC with pollution degree 1-2 accor
ding to IEC 60664-1
Caution!
The protection class 2 is only valid when the terminal compart
ment is closed.
UL approval E87056 , cULus Listed
Caution: This equipment is considered
as open-type equipment. It must be mounted within an enclos
ure, that is suitably designed for protection against internal fire
and personal injury resulting from accessibility to live parts
according UL 508.
CCC approval Certified by China Compulsory Certification (CCC)


Detection range min. 20 ... 200 mm
Detection range max. 20 ... 2000 mm
Adjustment range 200 ... 2000 mm
Background suppression max. + 10 % of the upper limit of the detection range
Light source IRED
Light type modulated infrared light , 880 nm
Switching voltage max. 250 V AC/DC
Switching current max. 2 A
Switching power DC: max. 50 W AC: max. 500 VA
Switching frequency f 25 Hz
Response time 20 ms
Timer function ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay