Switching element function PNP NO Rated operating distance sn 2 mm Installation embeddable Operating voltage UB 10 ... 30 V Switching frequency f 0 ... 1500 Hz Hysteresis H typ. 5% Reverse polarity protected reverse polarity protected Operating current IL 0 ... 100 mA Off-state current I r 0 ... 0.5 mA typ. 0.1 µA No-load supply current I0 ≤ 15 mA Indication of the switching state Multihole-LED, yellow Functional safety related parameters MTTFd 2730 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type Device connector M12 x 1 , 4-pin Protection degree IP67 |
|
Compliance with standards and directives Standard conformity Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Approvals and certificates UL approval cULus Listed, General Purpose |
Output polarity DC
Assured operating distance sa 0 ... 1.62 mm
Reduction factor rAl 0.45
Reduction factor rCu 0.35
Reduction factor r304 0.75
Nominal ratings
Short-circuit protection pulsing
Voltage drop Ud ≤ 3 V
Housing material brass, nickel-plated
Sensing face LCP
CSA approval cCSAus Listed, General Purpose
CCC approval Products with a maximum operating voltage of ≤36 V do not bear a
CCC marking because they do not require approval.