Effective detection range 0 ... 4 m Electrical specifications Operating voltage UB 10 ... 30 V DC No-load supply current I0 < 20 mA Output Voltage drop Ud ≤ 1.5 V DC Switching frequency f 500 Hz |
|
Compliance with standards and directi ves Standard conformity Product standard EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Approvals and certificates |
Reflector distance 0.05 ... 4 m
Threshold detection range 5.5 m
Reference target reflector C110-2
Light source LED
Light type modulated visible red light , 640 nm
Diameter of the light spot approx. 200 mm at 5.5 m
Angle of divergence approx. 2 °
Optical face frontal
Ambient light limit 30000 Lux
Functional safety related parameters
MTTFd 920 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operating display LED green, statically lit Power on
Function display LED yellow: lights up when receiving the light beam ; flashes
when falling short of the stability control; OFF when light beam
is interrupted
Switching type light/dark on
Signal output 2 PNP, complementary, short-circuit protected, open collectors
Switching voltage max. 30 V DC
Switching current max. 100 mA
Response time ≤ 1 ms
Ambient conditions
Ambient temperature -25 ... 60 °C (-13 ... 140 °F)
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Protection degree IP67
Connection connector M12 x 1, 4-pin
Material
Housing PC
Optical face PMMA
Connector plastic
Mass approx. 10 g
Protection class II, rated insulation voltage ≤ 250 V AC with pollution degree
1-2 according to IEC 60664-1
UL approval cULus Listed, Class 2 Power Source
CCC approval Products with a maximum operating voltage of ≤36 V do not
bear a CCC marking because they do not require approval.